Message Logical chassis firmware download has completed installation on rbridge-id
<rbridge IDs>.
Message Type LOG | VCS
Severity WARNING
Probable Cause Indicates that firmware upgrade has completed successfully.
Recommended
Action
No action is required.
SULB-1113
Message Logical chassis firmware download will be aborted due to failover on rbridge-id
<rbridge IDs>.
Message Type LOG | VCS
Severity WARNING
Probable Cause Indicates that firmware upgrade failed.
Recommended
Action
Execute the firmware recover or firmware activate command.
SULB-1114
Message Firmware installation has completed successfully on rbridge-id <rbridge IDs>.
Please run 'firmware activate' for firmware activation.
Message Type LOG | VCS
Severity INFO
Probable Cause Indicates that firmware upgrade has completed.
Recommended
Action
Execute the firmware activate command to activate the firmware.