Przeglądanie stron 165
150 Network OS Message Reference
53-1003227-01
ELD-1001
8
ELD Messages
ELD-1001
Message Interface <InterfaceName> is shut down by edge loop detection (ELD) for loop in
VLAN <VLAN ID>.
Message Type DCE
Severity INFO
Probable Cause Indicates that a loop has been detected by the edge loop detection (ELD) protocol on the specified
interface. The interface has been shut down.
Recommended
Action
Identify and fix the Layer 2 bridging loop and then re-enable the interface using the clear
edge-loop-detection command.
ELD-1002
Message Interface <InterfaceName> is auto-enabled by edge loop detection (ELD).
Message Type DCE
Severity INFO
Probable Cause Indicates that the interface on which a loop was detected has been auto-enabled based on the
configured shutdown time.
Recommended
Action
No action is required.