FW-1430
8
FW-1430
Message Switch status change contributing factor <string>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the switch is not in a healthy state. This occurred because the number of faulty
temperature sensors is greater than or equal to the policy set by the system-monitor command. A
temperature sensor is faulty when the sensor value is not in the acceptable range.
Recommended
Action
Replace the field-replaceable unit (FRU) with the faulty temperature sensor.
FW-1431
Message Switch status change contributing factor Fan: <Number Bad> bad.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the switch is not in a healthy state. This occurred because the number of faulty fans is
greater than or equal to the policy set by the system-monitor command. A fan is faulty when sensor
value is not in the acceptable range.
Recommended
Action
Replace the faulty or deteriorating fans.
FW-1432
Message Switch status change contributing factor Cid-Card: <Number Bad> bad.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the switch is not in a healthy state. This occurred because the number of faulty Chassis ID
(CID) cards is greater than or equal to the policy set by the system-monitor command.
Recommended
Action
Replace the faulty CID card.