Network OS Message Reference 121
53-1003227-01
C3-1017
8
C3-1017
Message Interface module in Slot-<slot string> failed due to unavailability of ports in
the internal trunk.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the specified interface module failed due to unavailability of ports in the internal trunk.
Recommended
Action
Whenever this error is observed persistently, power cycle the specified interface module using the
power-off and power-on commands. If the problem persists, replace the interface module.
C3-1019
Message <slot string>,C<chip index>: HW ASIC Chip TXQ FID parity error threshold reached
type = 0x<chip error type>.
Message Type LOG
Severity WARNING
Probable Cause Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade
the data traffic.
Recommended
Action
Reload the system at the next maintenance window.
C3-1020
Message <slot string>,P<port number>(<interface module port number>): Some non-critical
CRC with good EOF errors were observed: current:0x<last_crc_good_eof_cnt>,
last:0x<total_crc_good_eof_cnt>, thresh1:0x<threshold_used>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that some non-critical errors were detected in the hardware.
Recommended
Action
No action is required.