Network OS Message Reference 197
53-1003227-01
FSS-1010
8
FSS-1010
Message FSS Warning: <Warning Message>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that a fabric synchronization service (FSS) error may have occurred.
Recommended
Action
No action is required.
FSS-1011
Message All services complete the critical recoveries in <time taken for the critical
service recovery> sec.
Message Type LOG
Severity INFO
Probable Cause Indicates a non-disruptive failover with warm recovery.
Recommended
Action
If the time taken for critical service recovery is more than 8 seconds, contact your switch service provider.
FSS-1012
Message FSS transport flow hitting the threhold (<number of waiting requests>:<the current
xmb allocation size>:<total of KERNEL memory>:<total of ATOMIC memory>).
Message Type LOG | FFDC
Severity CRITICAL
Probable Cause Indicates that the underlying transport is not healthy.
Recommended
Action
Execute the copy support command and contact your switch service provider.
Przeglądanie stron 212