120 Network OS Message Reference
53-1003227-01
C3-1011
8
C3-1011
Message Detected a complete loss of credit on internal back-end VC: Slot <slot string>,
Port <port number>(<interface module port number>) vc_no=<vc number>
crd(s)lost=<credit(s)lost>.
Message Type LOG
Severity INFO
Probable Cause Indicates that all credits have been lost on the specified virtual channel (VC) and port.
Recommended
Action
No action is required. The link will be reset to recover the credits.
C3-1012
Message <slot string>,P<port number>(<interface module port number>): Link Timeout on
internal port ftx=<frame transmitted> tov=<real timeout value> (><expected
timeout value>) vc_no=<vc number> crd(s)lost=<credit(s) lost>
complete_loss:<complete credit loss>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that above normal errors were observed in hardware that may or may not impact the data
traffic.
Recommended
Action
Whenever this error is observed persistently, power cycle the specified interface module using the
power-off and power-on commands. If the problem persists, replace the interface module.
C3-1014
Message Link Reset on internal Port <slot string>,P<port number>(<interface module port
number>) vc_no=<vc number> crd(s)lost=<credit(s) lost>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that one or more credits were lost and the link is reset.
Recommended
Action
Whenever this error is observed persistently, power cycle the specified interface module using the
power-off and power-on commands. If the problem persists, replace the interface module.