
Network OS Message Reference 297
53-1003227-01
NS-1006
8
NS Messages
NS-1006
Message Duplicated WWN was detected with PID 0x<existing device PID> and 0x<new device
PID>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that an existing device has the same World Wide Name (WWN) as a new device that has come
online.
Recommended
Action
The switch will process the new process ID (PID) and leave the existing PID intact. Subsequent switch
operations will clean up the obsolete PID. However, administrators can check and remove devices with a
duplicated WWN.
NS-1009
Message NS has detected a device with node WWN as zero, PID 0x<device PID>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that a port has logged in with the node World Wide Name (WWN) as zero. Brocade Network
Advisor (BNA) will not show the port connectivity.
Recommended
Action
Check the device that logged in. The device could be misbehaving.
NS-1012
Message Detected duplicate WWPN [<WWPN>] - devices removed with PID 0x<existing device
PID> and 0x<new device PID>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the devices with the same World Wide Port Name (WWPN) have been removed from the
Name Server database.
Recommended
Action
Administrators should verify the reported devices with a duplicated WWPN.
Komentarze do niniejszej Instrukcji