
182 Network OS Message Reference
53-1003227-01
FCOE-1001
8
FCOE Messages
FCOE-1001
Message calloc failed for <object>.
Message Type DCE
Severity ERROR
Probable Cause Indicates a memory failure.
Recommended
Action
Check the switch memory status using the show process memory command.
FCOE-1010
Message Clean up of login failed for port:<port number>.
Message Type DCE
Severity ERROR
Probable Cause Indicates an invalid port number.
Recommended
Action
Execute the copy support command and restart the system. Contact your switch service provider.
FCOE-1019
Message FLOGI ignored as FCMAP not configured on FCoE VLAN.
Message Type DCE
Severity WARNING
Probable Cause Indicates that FCMAP is not configured on the Fibre Channel over Ethernet (FCoE) VLAN.
Recommended
Action
Configure FCMAP using the fcmap command.
Komentarze do niniejszej Instrukcji