332 Network OS Message Reference
53-1003227-01
PDM-1006
8
PDM-1006
Message Too many files in sync.conf.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the sync.conf configuration file contains too many entries.
Recommended
Action
Execute the firmware download command to reinstall the firmware.
If the message persists, execute the copy support command and contact your switch service provider.
PDM-1007
Message File not created: <file name>. errno=<errno>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the parity data manager (PDM) process failed to create the specified file.
Recommended
Action
Execute the firmware download command to reinstall the firmware.
If the message persists, execute the copy support command and contact your switch service provider.
PDM-1009
Message Cannot update Port Config Data.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the parity data manager (PDM) system call for setting port configuration (setCfg) failed.
Recommended
Action
Execute the firmware download command to reinstall the firmware.
If the message persists, execute the copy support command and contact your switch service provider.
PDM-1010
Message File open failed: <file name>, errno=<errno>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the parity data manager (PDM) process could not open the specified file.