Message Failed to unlock semaphore mutex: (<function name>).
Message Type DCE
Severity ERROR
Probable Cause Indicates that the specified function has failed to unlock the mutex (semaphore).
Recommended
Action
Reload or power cycle the switch.
SSMD-1005
Message SSM startup failed.
Message Type DCE
Severity ERROR
Probable Cause Indicates that the Data Center Ethernet (DCE) System Services Manager (SSM) has encountered an
unexpected severe error during basic startup and initialization.
Recommended
Action
Reload or power cycle the switch.
If the problem persists, download a new firmware version using the firmware download command.
SSMD-1006
Message SSM ASIC downlaod buffer overflow (size <required buffer size> > max <max buffer
size>) in function <function name>.
Message Type DCE
Severity ERROR
Probable Cause Indicates that the Data Center Ethernet (DCE) System Services Manager (SSM) has encountered an
unexpected severe error when fill in the I/O control (IOCTL) structure.
Recommended
Action
Reload or power cycle the switch.
If the problem persists, download a new firmware version using the firmware download command.