902 Multi-Service IronWare Switching Configuration Guide
53-1003036-02
ACL-based Inbound sFlow
23
Table 119 shows the output information provided by the show sflow command.
TABLE 119 sFlow information
Field Description
sFlow services The feature state, which can be one of the following:
disabled
enabled
sFlow management VRF Indication that sFlow is enabled to use the management VRF. Disabled
means that sFlow is using the non-management VRF instance.
sFlow management VRF name Management VRF name, if the management VRF is enabled on sFlow.
sFlow agent IP address The IP address that sFlow is using in the agent_address field of packets
sent to the collectors. Refer to “Source address”.
sFlow agent IPV6 address The sFlow agent IPv6 address is unspecified by default. If configured, it
will correspond to the IP address on the configured interface.
sFlow source IP address The sFlow source IP address corresponds to the IP address on the
configured interface. If an IP address is not configured on the interface,
then it will be unspecified. However, if the source interface is null0, then
it will be null0 on the interface.
sFlow source IPv6 address The sFlow source IPv6 address that corresponds to the IP address on
the configured interface. If an IP address is not configured, then the
interface will be unspecified. However, if the interface is null0, then the
configured interface will be null0.
UDP The sFlow source UDP port default is 8888.
Collector The collector information. The following information is displayed for each
collector:
IP address
UDP port
If more than one collector is configured, the line above the collectors
indicates how many have been configured.
Polling interval The port counter polling interval.
Configured default sampling rate The configured global sampling rate. If you changed the global sampling
rate, the value you entered is shown here.
UDP packets exported The number of sFlow export packets the device has sent.
NOTE: Each UDP packet can contain multiple samples.
sFlow samples collected The number of sampled packets that have been sent to the collectors.
sFlow ports The ports on which you enabled sFlow.
Global Sample Rate The global sampling rate for the device.
Port Sampling Rate The sampling rates of a port on which sFlow is enabled.
Hardware Sample Rate The actual sampling rate. This is the same as the Global Sample Rate