242 Multi-Service IronWare Switching Configuration Guide
53-1003036-02
About IEEE 802.1ad
9
Brocade(config)# esi ESI_1 encapsulation svlan
Brocade(config-esi-ESI_1)# single-flood-domain
Brocade(config-esi-ESI_1)# vlan 100
Brocade(config-esi-ESI_1)# tagged ethernet 1/3
Brocade(config-esi-ESI_1)# vlan 200
Brocade(config-esi-ESI_1)# tagged ethernet 1/4
Brocade(config-esi-ESI_1)# exit
Untagged ports
Packets from SVLAN port with only SVLAN tag (no CVLAN tag) are sent to only untagged ports in the
default ESI.
Default VLAN
Packets from SVLAN with default VLAN as CVLAN tag are sent to untagged ports in the default ESI.
No Default VLANs are allowed inside non-default ESIs.
Port-based Service Interface Super Aggregated
VLANs (SAV)
Using Port-based Service Interfaces is equivalent to using SAV in other Brocade products.
Port-based Service Interfaces can be used when mapping a port based interface to a single
Service VLAN Tag (S-TAG). When using a port-based service interface, it maps all VLAN-IDs from
incoming ports to a SVLAN as shown in “Port-based service interface”.
FIGURE 26 Port-based service interface
Sample configuration
Brocade(config)# tag-type tag2 ethernet 2/1
Brocade(config)# vlan 100
Brocade(config-vlan-100)# tagged ethernet 2/1
Brocade(config-vlan-100)# untagged ethernet 1/1
Brocade(config)# vlan 200
Brocade(config-vlan-200)# tagged ethernet 2/1
Brocade(config-vlan-200)#untagged ethernet 1/2