Multi-Service IronWare Switching Configuration Guide 535
53-1003036-02
ERP commands
15
Configuration example
NOTE
The VLAN CPU protection needs to be enabled on the VLANs.
Device 1 Configuration steps
CFM configuration:
Brocade#configure terminal
Brocade(config)#cfm-enable
Brocade(config-cfm)#domain-name erp id 1 level 1
Brocade(config-cfm-md-erp)#ma-name ma-erp link-ma priority 7
Brocade(config-cfm-md-erp-ma-ma-erp)#individual-link-monitoring
Brocade(config-cfm-md-erp-ma-ma-erp)#mep 101 down port eth 1/1
Brocade(config-cfm-md-erp-ma-ma-erp)#mep 102 down port eth 1/2
VLAN Configuration:
Brocade(config)#vlan 100
Brocade(config-vlan-100)#tag eth 1/1 eth 1/2
Brocade(config-vlan-100)#vlan-cpu-protection
ERP Configuration:
Brocade(config)#erp 1
Brocade(config-erp-1)#left-interface vlan 100 eth 1/1
Brocade(config-erp-1)#right-interface vlan 100 eth 1/2
Brocade(config-erp-1)#rpl-owner
Brocade(config-erp-1)#rpl vlan 100 eth 1/2
Brocade(config-erp-1)#flooding-enable
Brocade(config-erp-1)#fdb-flush-optimization
Brocade(config-erp-1)#dot1ag-compliance domain-name erp ma-name ma-erp
Brocade(config-erp-1)#enable