116 Brocade Network Advisor SMI Agent Developer’s Guide
53-1003159-01
Alert indications
4
BRCD13 A single device went offline.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=BROCADE and
MessageID=BRCD13
How to trigger: Telnet to the switch and
run the CLI portdisable portnumber
where the port is an F_Port.
AlertingManagedElement COP of Brocade_Node
AlertingElementFormat COP
AlertType Other
OtherAlertType Port Alert
AlertSubType Connected Port Offline
PerceivedSeverity 2 (Informational)
ProbableCause 123
SystemCreationClassName Brocade_Fabric
SystemName Fabric WWN
ProviderName Brocade_AlertIndication
Provider
OwningEntity BROCADE
Message A single device named
<WWN> went offline for
fabric named
<FabricWWN>
MessageArguments Device WWN, Fabric
WWN
BRCD16 A session (transaction) was aborted and
all changes made within that transaction
were discarded.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=BROCADE and
MessageID=BRCD16
How to trigger: Abort zone changes using
the CLI cfgabort or using the
Brocade_ZoneService.SessionControl
extrinsic method.
AlertingManagedElement COP of Brocade_Fabric
AlertingElementFormat COP
AlertType Other
OtherAlertType Zone Alert
AlertSubType Zone session aborted
PerceivedSeverity 2 (Informational)
ProbableCause 123
SystemCreationClassName Brocade_Fabric
SystemName Switch WWN
ProviderName Brocade_AlertIndication
Provider
OwningEntity Brocade
Message A zoning session was
aborted for fabric named
<WWN>
MessageArguments Switch WWN, port
statusFabric WWN
TABLE 14 Supported alert indications (Continued)