Brocade Network Advisor SMI Agent Developers Guide v12.3.0 Instrukcja Użytkownika Strona 123

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 178
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 122
Brocade Network Advisor SMI Agent Developer’s Guide 107
53-1003159-01
Alert indications
4
FC2
Configuration was enabled, and now this
configuration is the active configuration.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=SNIA and MessageID=FC2
How to trigger: Enable the zoning
configuration. You can also do this
through the CLIs zonadd, cfgsave, and
cfgenable.
AlertingManagedElement COP of Brocade_Fabric
AlertingElementFormat COP
AlertType Device Alert
OtherAlertType N/A
AlertSubType Config Enabled
PerceivedSeverity 5 (Major)
ProbableCause 123
SystemCreationClassName Brocade_Fabric
SystemName Fabric WWN
ProviderName Brocade_AlertIndication
Provider
OwningEntity SNIA
Message ZoneSet <ZoneSet
Name> was activated for
fabric <WWN>
MessageArguments ZoneSet name Fabric
WWN
FC5 Change in operational status for switch.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=SNIA and MessageID=FC5
AlertingManagedElement COP of Brocade_Switch
AlertingElementFormat COP
AlertType Device Alert
OtherAlertType N/A
AlertSubType Switch modified
PerceivedSeverity 5 (Major)
ProbableCause 123
SystemCreationClassName Brocade_Switch
SystemName Switch WWN
ProviderName Brocade_AlertIndication
Provider
OwningEntity SNIA
Message Switch <Switch Unique
Identifier> in Fabric
<Fabric Name> status
changed to <Switch
OperationalStatus>
MessageArguments Switch WWN, fabric
WWN, switch operational
status
TABLE 14 Supported alert indications (Continued)