300 Multi-Service IronWare Routing Configuration Guide
53-1003033-02
Displaying IPv4 IS-IS information
Level-2 Hello Multiplier The number by which the software multiplies the hello interval to
calculate the hold time set for Level-2 Hello PDUs sent on this circuit.
This parameter is not displayed for interfaces that are configured with a
Point-to-Point circuit type. This is because separate Level-2 Hello
messages are not sent on Point-to-Point interfaces. Consequently, "Hello
Interval", "Hello Multiplier", and "Authentication" parameters should
always be configured in the Level-1 mode for Point-to-Point interfaces.
Level-2 Designated IS The NET of the Level-2 Designated IS.
Level-2 DIS Changes The number of times the NET of the Level-2 Designated IS has changed.
Next IS-IS LAN Level-1 Hello Number of seconds before next Level-1 Hello PDU will be transmitted by
the Brocadedevice.
Next IS-IS LAN Level-2 Hello Number of seconds before next Level-2 Hello PDU will be transmitted by
the Brocade device.
Number of active Level-1 adjacencies The number of ISs with which this interface has an active Level-1
adjacency.
Number of active Level-2 adjacencies The number of ISs with which this interface has an active Level-2
adjacency.
Circuit State Changes The number of times the state of the circuit has changed.
Circuit State Adjacencies Changes The number of times an adjacency has started or ended on this circuit.
Rejected Adjacencies The number of adjacency attempts by other ISs rejected by the Brocade
device.
Circuit Authentication L1 failures The number of times the Brocade device rejected a circuit because the
authentication did not match the authentication configured for
Level-1on the Brocade device.
Circuit Authentication L2 failures The number of times the Brocade device rejected a circuit because the
authentication did not match the authentication configured for Level-2
on the Brocade device.
This parameter is not displayed for interfaces that are configured with a
Point-to-Point circuit type. This is because separate Level-2 Hello
messages are not sent on Point-to-Point interfaces. Consequently, "Hello
Interval", "Hello Multiplier", and "Authentication" parameters should
always be configured in the Level-1 mode for Point-to-Point interfaces.
Bad LSP The number of times the interface received a bad LSP from an IS at the
other end of the circuit. The following conditions can cause an LSP to be
bad:
• Invalid checksum
• Invalid length
• Invalid lifetime value
Control Messages Sent The number of IS-IS control PDUs sent on this interface.
Control Messages Received The number of IS-IS control PDUs received on this interface.
Hello Padding: The Hello Padding configuration, which can be:
• Enabled
• Disabled
IP Enabled If set to TRUE, the IP protocol is enabled for this circuit.
IP Address and Subnet Mask The IP address and subnet mask for this interface.
TABLE 42 IS-IS interface information (Continued)
This field... Displays...
Komentarze do niniejszej Instrukcji