Multi-Service IronWare Multiprotocol Label Switch (MPLS) Configuration Guide 267
53-1003031-02
Transit LSP statistics
1
When an option is used without a variable specified, the configuration parameters for the option
are shown for all elements that match the option are displayed. For instance, in the following
example the lsp option is used without a specified lsp-name variable. Consequently, the display
contains the configuration information for all three LSPs configured on the router.
Brocade# mpls config lsp
lsp frr1
to 10.4.2.1
cos 6
ipmtu 1028
traffic-eng max-rate 180 mean-rate 125
metric 5
shortcuts ospf
frr
bandwidth 80
hop-limit 55
enable
lsp lsp13d
to 10.3.3.2
primary mu1_to_mu3
cos 7
traffic-eng max-rate 250 mean-rate 120
no cspf
enable
lsp lsp12d
to 10.1.1.2
cos 7
traffic-eng max-rate 100 mean-rate 50
enable
Transit LSP statistics
Transit LSP statistics extends the ability to collect and display traffic statistics on a transit router for
both LDP and RSVP.
Brocade MLX series and NetIron XMR limitations
NOTE
Not all interface modules support transit LSP statistics. Gen-2 interface modules that do support
packet count, byte count and rate include the 24x10G, 2x100G, and 8x10G modules.
Refer to Table 36 for additional interface module and packet count support.