Modified PIM commands (Continued)TABLE 21
FastIron 08.0.xx FastIron 07.4.00 Note
[no] message-interval
seconds
default: 60 secs
allowed range: [10 - 65535]
secs
[no] message-interval
seconds
default: 60 secs
allowed range: [1 - 65535]
secs
Configures PIM prune wait timer. The allowed
range has been changed from [1-65535] seconds
to [10-65535] seconds.
[no] hardware-drop-
disable
[no] hardware-drop
Default: PMRI is enabled
Configures Passive Multicast Router Insertion
(PMRI). PMRI is enabled by default.
[no] rp-address address
[acl-num | acl-name]
[no] rp-address address
[std-acl-num [override]]
Configures static RP using ACL.
FastIron 07.4.00 supports only standard numbered
ACL, whereas in FastIron 08.0.xx, all ACLs
(standard, extended, numbered, and named) are
supported.
In FastIron 07.4.00, RP address learned from the
Bootstrap protocol takes precedence over static
RP, so override option was provided to give
precedence to static RP. In FastIron 08.0.xx,
static-RP takes precedence.
[no] rp-candidate
ethernet | ve | loopback
num
[no] rp-candidate
ethernet | ve | loopback
num [group-list std-acl-num]
Configures RP candidate using ACL.
In FastIron 07.4.00, ACLs can be used to limit RP
candidate for certain groups.
In FastIron 08.0.xx, this feature is not available.
So, RP candidate is for all the groups.
[no] system-max pim-
hw-mcache num
[no] system-max pim-
mcache num
Sets the maximum limit for the PIM mcache (flows)
that can be programmed in the hardware.
Interface level command
[no] ip pim [version] [no] ip pim [version]
Configures the PIM SM/DM version on particular
interface. PIM DM version 1 is not supported any
more. PIM-SM v2, PIM-DM v1, and PIM-DM v2 are
supported versions.
Deprecated PIM commands TABLE 22
Command Note
Global level command
[no] disable-pim
Disables the PIM operation without removing the PIM configuration.
[no] rp-address all
Removes all static RP configurations. In FastIron 08.0.xx, all static RP address
configuration have to be deleted individually.
Interface level command
Upgrade and downgrade considerations