Przeglądanie stron 318
Syslog messages
Brocade Syslog messages............................................................................................319
This section lists all of the Syslog messages. Note that some of the messages apply only to Layer 3
switches.
NOTE
This chapter does not list Syslog messages that can be displayed when a debug option is enabled.
The messages are listed by message level, in the following order, then by message type:
Emergencies (none)
Alerts
Critical
Errors
Warnings
Notifications
Informational
Debugging
Brocade Syslog messages
Message
num-modules modules and 1 power supply, need more
power supply!!
Explanation Indicates that the chassis needs more power supplies to run the modules
in the chassis.
The num-modules parameter indicates the number of modules in the
chassis.
Message Level Alert
Message
Fan num , location , failed
Explanation A fan has failed.
The num is the fan number.
The location describes where the failed fan is in the chassis.
Message Level Alert
Message
MAC Authentication failed for mac-address on
portnum
FastIron Ethernet Switch Administration Guide 319